HOT WINTER

HOME  :: CONTACT US ::  PERSIAN SITE

 

 

09CDF  

Air-Cooled Condensers - Quality and Value

11-128.5 Tons

 

 
With the 09CDF air -cooled condensers S.S.I offers a choice of 21 models with capacities from 11 to 128.5 ton for vertical and horizontal airflow. 09CDF condensers are manufactured to the highest quality standards and offer the following distinct advantages:
  • Heavy-duty construction with casing made from galva­nized sheet metal painted with baked enamel for maximum UV and corrosion resistance.

  • Advanced circuitry and fin design with a wide selection of fin and tube materials.
  • High-efficiency fan motors and propellers with opti­mized air management design.
  • Improved serviceability through large access doors for each fan motor section.
Technical Description

Coils

 

  • High performance aluminium fins and copper tubes, staggered tube arrangement.

  • One Schrader valve for each circuit.

  • Holding charge of minimum 1 bar.

  • Subcooling circuit (one additional row of tubes for approx. 12.5F subcooling at standard rating conditions of Δt = 27F, all connections factory made).

Fans
  • 36 in diameter with high-efficiency blade design.

  • Extra deep fan shroud for optimum air flow.

Fan Motors

  • Standard voltage 400 V (± 10%), three phase, 50 Hertz

  • Operating in - 40° F to 122° F ambient temperature.     

  • Protection IP55 (IEC 34-5), Class F (IEC 85 and IEC 34-1).

  • Each motor mounted on rigid four cross beam and wired to a terminal box close to the refrigerant connections.

  • Maximum 6 starts per hour.

  • Motors must run at least two hours per month.

Casing

  • Self supporting design, fan sections individually partitioned.

  • Casing made from galvanized sheet metal painted with baked enamel for maximum UV and corrosion resistance.

  • Lifting lugs for all models provided.

  • Service access doors for each fan motor.

Options

  •  Multiple circuits.

Model Number Nomenclature

Sound pressure level

Ambient temperature (F) 60 70 80 90 100 110 120    
Factor f1: 1.032 1.014 0.993 0.971 0.949 0.929 0.91    
Correction factor for Δt:
Δt (f): 15 20 25 30 35        
Factor f2: 0.555 0.741 0.926 1.111 1.296        
Correction factor for different refrigerants:
Refrigerant R-134a R-22 R-502            
Factor f3: 0.954 1 0.975            
Correction factor for different altitudes:
Altitude (ft) 0 1000 2000 3000 4000 5000 6000 7000 8000
Factor f4: 1 0.980 0.959 0.936 0.917 0.896 0.875 0.845 0.834
2.  The required nominal capacity to be looked up in the selection data is:
  Qn = Q/(f1 x f2 x f3 x f4)  
  (Q= your required capacity)  

 

 

 

Cooling Towers

 Propeller Fan

 

 Centrifugal Fan(HCC)

 

 SAFCT Towers

 

SAFCT Towers

Absorbtion  
Reciprocating HK-HL  
Reciprocating HR-HS  

Cooling Unit

Single Packege  
Split Packege  

Fan Coil

Ducted Fan Coil  
Room Fan Coil  

Air Handling Units

39 FD  
39 E  

Air Condensers

 

 

© Copyright 2009 Hot Winter. All Rights Reserved.